The pMC Master Controller is a comprehensive system that controls the total function of a dust collector. This advanced system monitors all the functions of a dust collectors and has a comprehensive numbers of built-in selectable alarms. These alarms can be general or critical alarms.

The enclosure has been re-engineered and radically redesigned.

The chart below highlights the five (5) different configurations and any system can be easily upgraded when necessary.

The pMC is available in a number of option and can be easily upgraded from the basic pMC-o  unit to the most advanced controller pMC-cw.

pMC-o

 It encompasses the following features:

  • Timer with 10 outputs extandable to 300
  • On demand cleaning
  • Fully selectable alarms
  • Code protected
  • Sequential or arbitrary pulsing mode
  • The inputs can be customised
  • Auto/manual function
  • Real time clock
  • Default values

Feature

PMC-o

PMC-t

PMC-c

PMC-I

PMC-w

Sequential timer

Differential pressure

Inputs analogue

Inputs digital

Output analogue

Output digital

Tube cleaner

 

Data logging

 

 

Remote monitoring

 

 

 

Remote diagnosis

 

 

 

Remote setting

 

 

 

Wireless

 

 

 

 

SPECIFICATIONS:

TIMER

  • No of valves: 1 - 300
  • ON time: 5 – 999ms
  • OFF time 1: 1 – 999s
  • OFF time 2 (fast): 1 – 999s
  • Pulsing mode: Sequential or Arbitrary
  • Clean after shutdown: 1 – 255 cycles

ON DEMAND CLEANER

  • DP differential pressure: Kpa, mm H2O or inWG
  • Ultra low level 
  • Low level: pulsing stops
  • High level 1: pulsing starts
  • High level 2: pulses faster
  • Alarm level
  • Tube Cleaner: duration (s) and interval (mins)

EXTERNAL INPUTS

                                                                            digital                            analog
                                                                     closed contact                       4-20mA

  • Clean down cycle                                    √
  • Air Flow                                                      √                                     √
  • Auxiliary                                                      √                                     √
  • Dust particle detector                              √                                     √
  • Header pressure                                      √                                    √
  • Hopper temp.                                            √                                     √

OUTPUTS

  • Solenoid valves: 24VDC
  • System active: relay contact
  • Differential pressure: 4-20mA
  • Alarms: relay contact
  • 24VDC

SLAVES

  • up to 10 output each (24VDC)
  • up to 25 slaves
  • RS485 2 wire (master & slave communication)

DISPLAY - graphic 

In normal ‘RUN ‘ mode the following parameters are displayed:

  • System mode – Manual or Auto
  • System Halted or Pulsing
  • No of next valve to trigger
  • Differential pressure value
  • Differential pressure mode
  • Tube cleaner count

ALARMS

Selectable as General (G) or Critical (C) alarm

  • Air flow: G or C
  • Auxiliary: G or C
  • Header pressure: G or C
  • Hopper Temperature: G or C
  • Hopper level: G or C
  • Dust particles: G or C
  • Moisture detector: G or C
  • Solenoid valve: G or C
  • Ultra low pressure: G or C
  • Differential pressure: G or C
  • Broken bag row: G or C
  • Solenoid failure – Electrical or mechanical    

 